< ciso
brief />
Tag Banner

All news with #denial of service tag

86 articles · page 5 of 5

Siemens IEM-OS DoS Vulnerability (CVE-2025-48976) Advisory

⚠️ Siemens Industrial Edge Management OS (IEM-OS) contains an allocation-of-resources vulnerability in Apache Commons FileUpload that can be triggered remotely to cause a denial-of-service condition. The issue is tracked as CVE-2025-48976 with a CVSS v4 base score of 8.7 and a CVSS v3.1 vector indicating an availability-only impact. Siemens reports all IEM-OS versions affected and recommends migrating to IEM-V, limiting access to trusted systems, and following Siemens' operational security guidance. CISA reiterates minimizing network exposure, using network segmentation and firewalls, and employing secure remote access methods.
read more →

Schneider Electric EcoStruxure Vulnerabilities and Fixes

⚠️ CISA published an advisory on two vulnerabilities in Schneider Electric EcoStruxure products that could enable a denial-of-service condition and the exposure of sensitive credentials. The issues are tracked as CVE-2025-8449 (uncontrolled resource consumption) and CVE-2025-8448 (sensitive information exposure). Affected Enterprise Server and Workstation versions should be updated to the fixed releases (for example 7.0.2.348, 6.0.4.10001 (CP8), 5.0.3.17009 (CP16)). If patches cannot be applied immediately, implement strong access controls, network segmentation, MFA where available, and continuous monitoring.
read more →

Rockwell ControlLogix 5580 NULL Pointer DoS Vulnerability

⚠️ A NULL pointer dereference vulnerability (CVE-2025-9166) in Rockwell Automation ControlLogix 5580 version 35.013 can cause the controller to enter a major, nonrecoverable fault resulting in denial of service. CISA reports a CVSS v4 base score of 8.2 and notes remote exploitability with low attack complexity. Rockwell recommends updating to version 35.014 or later and applying security best practices; CISA advises minimizing network exposure, isolating control networks, and using secure remote access methods.
read more →

Schneider Electric Modicon M340: FTP Input Validation Flaw

⚠️ Schneider Electric disclosed an Improper Input Validation vulnerability in Modicon M340 controllers and several communication modules that can be triggered by a specially crafted FTP command. Tracked as CVE-2025-6625 with a CVSS v4 base score of 8.7, the flaw enables a remote denial-of-service with low attack complexity. Schneider released firmware fixes for the BMXNOE0100 (v3.60) and BMXNOE0110 (v6.80) modules, which require device reboot; remediation for other affected products is planned. CISA recommends disabling FTP when not needed, blocking or segmenting port 21, using VPNs for remote access, applying vendor updates where available, and following ICS hardening and risk-assessment practices before making changes.
read more →

Mitsubishi MELSEC iQ-F CPU Module Denial-of-Service

🔒 CISA published Advisory ICSA-25-233-01 on August 21, 2025 describing a Denial-of-Service vulnerability (CVE-2025-5514, CVSS v3 5.3) in the Mitsubishi Electric MELSEC iQ-F Series CPU module web server. An attacker can send specially crafted HTTP requests that exploit an Improper Handling of Length Parameter Inconsistency to delay processing and prevent legitimate users from accessing the web server. Mitsubishi Electric reports no plans to release a fix and advises customers to restrict network exposure, use IP filtering and VPNs, and limit physical access. CISA recommends isolating control networks behind firewalls and minimizing internet exposure.
read more →

Rockwell Automation FLEX 5000 I/O: Input Validation Flaw

⚠️ Rockwell Automation has disclosed two improper input validation vulnerabilities in the FLEX 5000 I/O modules (5069-IF8 and 5069-IY8) assigned CVE-2025-7861 and CVE-2025-7862. Successful exploitation can remotely induce a fault state that requires a power cycle to recover, producing a denial-of-service condition. Both issues carry elevated CVSS v4 scores (8.7) and are exploitable with low attack complexity. Rockwell recommends upgrading affected modules to V2.012 or later and following established security best practices.
read more →