CISA Issues Six New Industrial Control Systems Advisories

🔔 CISA released six Industrial Control Systems (ICS) advisories detailing current security issues, vulnerabilities, and potential exploits affecting multiple vendors and products. The advisories cover Schneider Electric products (including EcoStruxure Machine SCADA Expert, Pro-face BLUE Open Studio, and PowerChute Serial Shutdown), Shelly Pro devices, and METZ CONNECT hardware. One advisory is an update (B) to a prior Schneider Electric notice. Users and administrators are encouraged to review the technical details and apply recommended mitigations promptly.
read more →

Shelly Pro 4PM DoS Vulnerability (CVE-2025-11243)

⚠ A vulnerability in Shelly Pro 4PM (CVE-2025-11243) can cause device reboots and denial-of-service conditions. Due to insufficient input bounds checking in the device's JSON parser, specially crafted RPC requests can trigger memory overallocation and force a reboot. Devices running firmware prior to v1.6 are affected; CISA notes the exploit is reachable from adjacent networks with low attack complexity. Operators should update to v1.6.0 or later and limit network exposure.
read more →

CISA Releases Four Industrial Control Systems Advisories

🔔 CISA released four Industrial Control Systems (ICS) advisories covering Advantech DeviceOn iEdge, Ubia Ubox, ABB FLXeon Controllers, and an update for Hitachi Energy Asset Suite. Each advisory provides technical details on identified vulnerabilities and recommended mitigations. Users and administrators are urged to review the advisories and apply mitigations promptly.
read more →

ABB FLXeon Devices: Multiple Remote-Access Vulnerabilities

ABB FLXeon devices are affected by multiple high-severity vulnerabilities, including hard-coded credentials, MD5 password hashing without proper salt, and improper input validation that can enable remote code execution. Combined CVSS v4 scores reach up to 8.7 and successful exploitation could allow remote control, arbitrary code execution, or device crashes. ABB and CISA advise disconnecting Internet-exposed units, applying the latest firmware, enforcing physical access controls, and using secure remote-access methods such as properly configured VPNs.
read more →

Falcon for XIoT Enhances OT Visibility and Speed at Scale

🔍 Falcon for XIoT introduces zero-touch asset discovery, native segmentation visibility, and a unified OT/XIoT view to reduce blind spots across industrial networks. The solution leverages DHCP data and the existing Falcon sensor to build continuous, agentless inventories and to monitor inter-device traffic without manual scan configuration. These enhancements aim to accelerate detection, simplify operations, and provide richer context for faster security decisions across IT, OT, and XIoT environments.
read more →

CISA Releases Five Industrial Control Systems Advisories

🔔 CISA released five Industrial Control Systems (ICS) advisories on November 4, 2025, providing timely information on vulnerabilities, impacts, and mitigations for affected products. The advisories address Fuji Electric Monitouch V-SFT-6, Survision License Plate Recognition Camera, Delta Electronics CNCSoft-G2, Radiometrics VizAir, and IDIS ICM Viewer. Users and administrators are urged to review the technical details and implement recommended mitigations and compensating controls to reduce exposure and protect operational systems.
read more →

Delta Electronics CNCSoft-G2 Stack Overflow Advisory

⚠️ Delta Electronics and CISA warn of a stack-based buffer overflow in CNCSoft-G2 (CVE-2025-58317) affecting versions 2.1.0.27 and earlier. When a user opens a specially crafted file, an attacker could execute arbitrary code in the context of the affected process; the vulnerability received a CVSS v4 base score of 8.5 and is characterized by low attack complexity. Delta recommends updating to Version 2.1.0.34 or later. CISA advises minimizing network exposure for control systems, isolating control networks, and using secure remote access methods.
read more →

Fuji Electric Monitouch V-SFT-6 Buffer Overflow Advisory

⚠️ Fuji Electric Monitouch V-SFT-6 (v6.2.7.0) contains two buffer overflow vulnerabilities — a heap-based and a stack-based overflow — triggered by specially crafted project files. Identified as CVE-2025-54496 and CVE-2025-54526, both carry CVSS v3.1 scores of 7.8 and CVSS v4 scores of 8.4. Successful exploitation could crash the HMI and may permit code execution; the vendor issued fixes in V6.2.8.0 and recommends updating to V6.2.9.0 or later.
read more →

Hacktivists Target Internet-Exposed Industrial Controls

⚠️ The Canadian Centre for Cyber Security warns hacktivists are increasingly exploiting internet-accessible industrial control systems (ICS), citing recent intrusions that affected a water utility, an oil and gas automated tank gauge (ATG), and a farm's grain-drying silo. Attackers manipulated pressure, fuel-gauge, and environmental controls, creating safety and service disruptions. The alert urges secure remote access via VPNs with MFA and inventories of OT assets. Provincial and municipal coordination is recommended to protect sectors lacking cybersecurity oversight.
read more →

CISA Releases Two ICS Advisories on ISO 15118-2 and TropOS

🛡️ CISA released two Industrial Control Systems advisories addressing the International Standards Organization ISO 15118-2 standard and Hitachi Energy TropOS. The advisories provide timely information on security issues, vulnerabilities, and potential exploits affecting ICS components. Administrators and operators are urged to review the advisories for technical details and recommended mitigations to protect operational environments.
read more →

Hitachi Energy TropOS Command Injection and Privilege Issues

⚠️ Hitachi Energy's TropOS wireless devices contain multiple vulnerabilities — including OS command injection and improper privilege management — that can be exploited remotely by authenticated users to obtain root access. Affected 4th Gen firmware versions up to 8.9.6.0 are vulnerable (CVE-2025-1036, CVE-2025-1037, CVE-2025-1038); CVSS v4 scores reach 8.7. Hitachi Energy advises immediate update to version 8.9.7.0, and CISA recommends isolating devices, minimizing network exposure, and following ICS security best practices.
read more →

CISA Releases Three ICS Advisories on Schneider, Vertikal

🔔 CISA released three Industrial Control Systems (ICS) advisories addressing multiple vulnerabilities that may affect operational technology safety and availability. The advisories cover ICSA-25-301-01 Schneider Electric EcoStruxure, ICSMA-25-301-01 Vertikal Systems Hospital Manager Backend Services, and an update to ICSA-24-352-04 Schneider Electric Modicon (Update B). Administrators and asset owners should review the technical findings, assess exposure, and apply recommended mitigations promptly to reduce operational risk.
read more →

Delta ASDA-Soft Stack Overflow Vulnerabilities (2025)

⚠️ Delta Electronics' ASDA-Soft contains two stack-based buffer overflow vulnerabilities (CVE-2025-62579, CVE-2025-62580) affecting versions 7.0.2.0 and earlier. Both issues were assigned a CVSS v4 base score of 8.4 and can allow writing outside the intended stack buffer when a valid user opens a crafted project file. Exploitation requires local access and user interaction; no public exploitation has been reported to CISA. Delta has released ASDA-Soft v7.1.1.0 and users should update and apply network isolation and standard email/attachment precautions.
read more →

NIHON KOHDEN CNS-6201 NULL Pointer DoS Advisory Update

⚠️ A remote NULL pointer dereference in NIHON KOHDEN CNS-6201 central monitors can be triggered by a specially crafted UDP packet, causing the monitoring process to terminate and producing a denial-of-service. The issue is unauthenticated, reproducible when UDP is reachable, and is tracked as CVE-2025-59668 with CVSS v4 8.7. Vendor support for affected versions has ended; users should migrate to successor products or apply strict network-level mitigations such as isolation, boundary devices, and careful traffic monitoring.
read more →

CISA Issues Eight New Industrial Control Systems Advisories

🔔 CISA released eight Industrial Control Systems advisories addressing vulnerabilities and updates across multiple vendors and products, including AutomationDirect, ASKI Energy, Veeder-Root, Delta Electronics, NIHON KOHDEN, Schneider Electric, and Hitachi Energy. The notices cover new findings and several updates (for example, Update A and Update C) and list ICSA/ICSMA identifiers for each advisory. Administrators and asset owners should review the technical details, apply available patches or vendor mitigations, and reinforce network segmentation, access controls, and monitoring to reduce exposure.
read more →

ASKI Energy ALS-Mini S4/S8: Missing Authentication Flaw

⚠ An unauthenticated access vulnerability in the embedded web server of ASKI Energy ALS‑Mini‑S4 and ALS‑Mini‑S8 IP controllers allows remote actors to read and modify device configuration, potentially yielding full control. Tracked as CVE-2025-9574, the issue is a Missing Authentication for Critical Function (CWE‑306) with a CVSS v4 base score of 9.9. ABB reports these products reached end of life in 2022 and will not be patched; operators should remove internet exposure, place devices behind firewalls or secure proxies that enforce authentication and logging, restrict access to whitelisted IPs, monitor for unauthorized access with IDS/IPS, or physically disconnect the Ethernet port if web features are not required.
read more →

AutomationDirect Productivity Suite: Multiple High-Risk Flaws

⚠️ AutomationDirect's Productivity Suite and several Productivity PLC models contain multiple high-severity vulnerabilities — including relative path traversal (ZipSlip), a weak password recovery mechanism, incorrect permission assignment, and binding to an unrestricted IP address. Exploitation could allow remote attackers to read, write, or delete files, execute arbitrary code, or gain full control of projects. AutomationDirect has released updates (Productivity Suite v4.5.0.x and newer) and recommends applying the latest firmware and implementing network isolation and firewall/NAC controls if immediate upgrades are not possible.
read more →

Veeder-Root TLS4B: Remote Command Injection and 2038 Bug

🔒 Veeder-Root's TLS4B Automatic Tank Gauge System contains two serious vulnerabilities: a SOAP-based command injection (CVE-2025-58428) that allows remote authenticated attackers to execute system-level commands, and an integer overflow/2038 time wraparound (CVE-2025-55067) that can disrupt authentication and core functions. The command injection carries very high severity (CVSS v3.1 9.9 / CVSS v4 9.4); Veeder-Root recommends upgrading to Version 11.A. For the time-related overflow, Veeder-Root is developing a patch and advises applying network-security best practices, isolating devices, and restricting access until a fix is available.
read more →

Siemens SIMATIC S7-1200 Vulnerabilities and Patches Updates

⚠️ Siemens has published an advisory for SIMATIC S7-1200 CPU V1/V2 devices describing two high-severity vulnerabilities: an Improper Input Validation flaw (CVE-2011-20001) that can force a controller into a stop/defect state via malformed HTTP traffic, and an Authentication Bypass by Capture-Replay (CVE-2011-20002) that allows replay of engineering commands. CVSS v4 scores are high (up to 8.7); Siemens recommends updating firmware (V2.0.3/V2.0.2) and disabling the web server where possible, while CISA advises network segmentation, firewalling, and avoiding direct Internet exposure.
read more →

Rockwell Compact GuardLogix 5370 Uncaught Exception

⚠️ Rockwell Automation has disclosed an uncaught exception vulnerability in Compact GuardLogix 5370 controllers that can be triggered by a crafted CIP unconnected explicit message and may cause a non‑recoverable fault resulting in denial-of-service. The issue is tracked as CVE-2025-9124 and carries a CVSS v4 base score of 8.7, indicating remote exploitability with low complexity. Rockwell recommends upgrading affected devices to firmware 30.14 or later; organizations unable to upgrade should follow vendor security best practices and apply network isolation measures.
read more →