Festo CPX-CEC-C1 and CPX-CMXX Privilege Flaw — Remote

⚠️ Festo CPX-CEC-C1 and CPX-CMXX devices contain an improper privilege management vulnerability (CWE-269) that permits unauthenticated remote access to critical webserver functions and may cause a denial of service. The issue is identified as CVE-2022-3079 with a CVSS v3.1 base score of 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/A:H). Festo currently has no firmware fix planned; recommended mitigations include restricting access to TCP port 80 and replacing affected units with specified follow-up products.
read more →

Seven Nations Publish Unified OT Security Guidance

🛡️ National cybersecurity agencies from seven countries released unified operational technology (OT) security guidance on 29 September, aimed at practitioners who deploy or operate OT equipment and systems. The document is organised around five core principles and supplies step-by-step actions for OT security teams to strengthen resilience. It emphasises creating and maintaining a definitive record that covers asset classification, connectivity mapping, system architecture and third-party risks.
read more →

CISA and NCSC Joint Guidance on Securing OT Systems

🔒 CISA, the FBI, the UK NCSC, and international partners published joint guidance titled Creating and Maintaining a Definitive View of Your Operational Technology (OT) Architecture. The guidance explains how organizations can use data sources such as asset inventories and manufacturer-provided resources, including software bill of materials, to create and maintain an accurate OT record. It highlights benefits like improved risk assessment, prioritization of critical and exposed systems, and stronger architectural controls, and recommends cross-team collaboration and alignment with IEC 62443 and ISO/IEC 27001.
read more →

CISA Releases One Industrial Control Systems Advisory

🔔 CISA released one Industrial Control Systems advisory on September 25, 2025 addressing Dingtian DT-R002. The advisory, ICSA-25-268-01, provides technical details on identified vulnerabilities and recommended mitigations for affected ICS devices. Administrators and operators are encouraged to review the advisory promptly and apply mitigations to reduce operational risk. This product is provided subject to CISA's Notification and Privacy & Use policies.
read more →

Dingtian DT-R002 Relay Board: Credentials Disclosure Risk

⚠️ CISA warns that the Dingtian DT-R002 relay board contains two Insufficiently Protected Credentials vulnerabilities (CVE-2025-10879, CVE-2025-10880) that allow unauthenticated attackers to retrieve a username and extract the proprietary protocol password. Both flaws affect all versions, are remotely exploitable with low complexity, and carry CVSS v4 base scores of 8.7. Dingtian has not engaged with CISA; users should restrict HTTP (TCP/80) and the Dingtian protocol on UDP/60000–60001, isolate devices from the internet, and follow ICS defensive best practices.
read more →

CISA Issues Six New Industrial Control Systems Advisories

🔔 CISA released six Industrial Control Systems (ICS) advisories on September 23, 2025, providing timely information on security issues, vulnerabilities, and potential exploits across multiple product families. The advisories cover AutomationDirect CLICK PLUS, Mitsubishi Electric MELSEC‑Q Series CPU Module, Schneider Electric SESU, Viessmann Vitogate 300, and two updates for Hitachi Energy RTU500 Series. Users and administrators are urged to review each advisory for technical details and apply recommended mitigations promptly.
read more →

Viessmann Vitogate 300: OS Command Injection Risks

🚨 CISA published an advisory on September 23, 2025, describing high‑severity vulnerabilities in Viessmann's Vitogate 300 gateway. The advisory identifies an OS command injection (CWE‑78, CVE‑2025‑9494) and a client‑side enforcement bypass (CWE‑602, CVE‑2025‑9495) that can enable command modification or unexpected client–server interactions. A CVSS v4 base score of 8.7 is reported overall, and affected devices running versions prior to 3.1.0.1 should be upgraded. CISA notes these issues are not remotely exploitable and recommends updating to 3.1.0.1 and implementing network hardening controls.
read more →

Mitsubishi MELSEC-Q CPU Module Denial-of-Service Risk

⚠️ CISA advises that a denial-of-service vulnerability (CVE-2025-8531) affects Mitsubishi Electric MELSEC-Q Series CPU modules when the user authentication function is enabled, due to improper handling of a length parameter (CWE-130). The issue has a CVSS v3.1 base score of 6.8 (AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H) and is exploitable remotely but characterized by high attack complexity. Mitsubishi has identified fixed units with serial ranges beginning '27082' or later and recommends migrating to the successor MELSEC iQ-R Series where updates are unavailable; organizations should apply network-access restrictions and defense-in-depth mitigations.
read more →

Schneider Electric SESU Link-Following Flaw CVE-2025-5296

⚠ Schneider Electric has released an update addressing a link‑following vulnerability (CVE‑2025‑5296) in SESU that could allow an authenticated, low‑privileged actor to write arbitrary data to protected locations. The issue, rated CVSS v3.1 base score 7.3, affects SESU versions prior to 3.0.12 and numerous Schneider Electric products that bundle SESU. Version 3.0.12 contains the fix; apply the update or restrict access to the installation directory and follow CISA mitigation guidance.
read more →

AutomationDirect CLICK PLUS Firmware Vulnerabilities Identified

🔒 AutomationDirect has disclosed multiple vulnerabilities in the CLICK PLUS series affecting firmware releases prior to v3.71. Issues include cleartext credential storage, a hard-coded AES key, an insecure RSA implementation, a predictable PRNG seed, authorization bypasses, and resource exhaustion flaws. CVSS v4 severity reaches 8.7 for the most critical cryptographic and key-generation weaknesses. AutomationDirect and CISA recommend updating to v3.80 and applying network isolation, access restrictions, logging, and endpoint protections until patches are deployed.
read more →

CISA Issues Nine New ICS Advisories on Sep 18, 2025

🛡️ CISA released nine Industrial Control Systems (ICS) advisories on September 18, 2025, detailing vulnerabilities, exploits, and mitigations affecting multiple vendors and products. The advisories cover Westermo WeOS, Schneider Electric Saitel RTUs, Hitachi Energy Asset and Service Suites, Cognex In‑Sight devices, Dover Fueling Solutions ProGauge MagLink LX4 devices, plus updates for rail linking protocols and Mitsubishi FA engineering tools. Administrators and operators are urged to review the technical details and apply recommended mitigations promptly to reduce operational and safety risk.
read more →

Schneider Electric Saitel RTU OS Command Injection

⚠️ Schneider Electric disclosed OS command injection vulnerabilities in Saitel DR and Saitel DP RTUs that could allow execution of arbitrary shell commands when BLMon is invoked in an SSH session. Two issues (CVE-2025-9996, CVE-2025-9997) carry a CVSS v4 base score of 5.8 (v3.1 6.6). Affected firmware versions are Saitel DR <= 11.06.29 and Saitel DP <= 11.06.33; fixed firmware releases are available and require a reboot. Schneider recommends restricting BLMon access, firewalling SSH, and following standard patching and ICS best practices.
read more →

CISA Releases Eight ICS Advisories for September 16, 2025

🔔 CISA released eight Industrial Control Systems advisories on September 16, 2025, providing technical descriptions of vulnerabilities and vendor mitigations. The advisories affect products from Schneider Electric, Hitachi Energy, Siemens, and Delta Electronics, and include issues ranging from OpenSSL-related flaws to product-specific defects. One advisory is an update for Galaxy VS/VL/VXL (ICSA-25-140-07 Update A). Administrators are urged to review the advisories and apply recommended mitigations promptly to reduce operational risk.
read more →

CISA Issues Eleven Industrial Control Systems Advisories

🔔 CISA released eleven Industrial Control Systems (ICS) advisories on September 11, 2025, offering timely technical details about vulnerabilities, exploits, and mitigations. The advisories span multiple vendors and product families, including Siemens (SIMOTION Tools, SIMATIC SIVaaS, SINAMICS, SINEC OS, Industrial Edge, UMC, Apogee PXC/Talon TC), Schneider Electric (EcoStruxure, Modicon M340 variants), and Daikin (Security Gateway). Administrators and asset owners are urged to review the advisories, apply vendor patches or recommended mitigations, and strengthen segmentation and monitoring to reduce operational risk.
read more →

CISA Releases Fourteen ICS Advisories — September 9, 2025

🔔 CISA released fourteen Industrial Control Systems (ICS) advisories on September 9, 2025, providing timely information on security issues, vulnerabilities, and potential exploits affecting critical industrial products. The set includes advisories for Rockwell Automation (ThinManager, Stratix IOS, FactoryTalk families, CompactLogix, ControlLogix, Analytics LogixAI, 1783-NATR), Mitsubishi Electric, Schneider Electric, ABB, and others. Administrators are urged to review the advisories for technical details, CVE references, and recommended mitigations, and to prioritize patching, configuration changes, and compensating controls to reduce operational risk.
read more →

CISA Issues Five ICS Advisories on Critical Vulnerabilities

⚠ CISA released five Industrial Control Systems (ICS) advisories on September 4, 2025, detailing vulnerabilities, impacts, and recommended mitigations for multiple OT products and protocols. The advisories address Honeywell OneWireless WDM, Mitsubishi Electric/ICONICS products, Delta Electronics COMMGR, Honeywell Experion PKS, and the End-of-Train/Head-of-Train Remote Linking Protocol. Several notices are updates (A/B) that include revised technical analysis and vendor-supplied mitigations. Administrators are urged to review the advisories promptly and apply recommended controls.
read more →

Delta EIP Builder XXE Vulnerability (CVE-2025-57704)

🔒 Delta Electronics' EIP Builder (versions 1.11 and earlier) contains an XML External Entity (XXE, CWE-611) vulnerability tracked as CVE-2025-57704 with a CVSS v4 base score of 6.7 and low attack complexity. The flaw can allow processing of malicious external entities and potential disclosure of sensitive information; exploitation requires local access and user interaction. Delta has released v1.12 to address the issue, and CISA recommends applying the update and following ICS defensive practices.
read more →

Fuji Electric FRENIC-Loader 4 Deserialization Vulnerability

⚠️ Fuji Electric's FRENIC-Loader 4 (versions prior to 1.4.0.1) contains a deserialization of untrusted data vulnerability (CVE-2025-9365) that can allow arbitrary code execution when a crafted file is imported. CISA assigns a CVSS v4 base score of 8.4 and reports the issue has low attack complexity but is not remotely exploitable. Researcher kimiya, working with Trend Micro ZDI, reported the flaw. Fuji Electric advises updating to v1.4.0.1 and CISA recommends network segmentation, minimizing exposure, using up-to-date VPNs, and performing impact analysis.
read more →

CISA Releases Four ICS Advisories on September 2, 2025

🛡️ CISA released four Industrial Control Systems (ICS) advisories on September 2, 2025, detailing vulnerabilities and recommended mitigations for Delta Electronics EIP Builder, Fuji Electric FRENIC-Loader 4, SunPower PVS6, and an update to Hitachi Energy Relion 670/650 and SAM600-IO Series. Each advisory includes technical analysis, affected versions, and practical guidance to reduce exploitation risk. Administrators and asset owners are urged to review the notices, prioritize affected systems, and apply vendor-recommended mitigations promptly.
read more →

SunPower PVS6 Hard-Coded Credentials Vulnerability

🔒 CISA warns of a high-severity vulnerability in SunPower PVS6 inverters (CVE-2025-9696) caused by hard-coded credentials in the Bluetooth Low Energy (BLE) interface. An attacker within Bluetooth range can exploit published protocol details and fixed encryption parameters to gain full device access, and CISA reports a CVSS v4 base score of 9.4. Successful exploitation could allow firmware replacement, disabling power production, modifying grid or firewall settings, creating SSH tunnels, and manipulating attached devices. SunPower did not respond to coordination; CISA advises minimizing network exposure, isolating control systems, using secure remote access methods such as up-to-date VPNs, and applying targeted intrusion detection and ICS best practices.